Welch Laboratory Fluid Handling

Precision in motion.
Meet the LP500.

Reliable, controlled liquid transfer for demanding laboratory applications. The new Welch LP500 peristaltic pump series combines digital speed control, convenient tubing replacement and dependable operation in one compact system.

Available in low-flow and high-flow configurations. Contact CompreVac for product selection and availability.

Welch LP500 laboratory peristaltic pump
NEW SERIES • LP500-L / LP500-H
0.2% Speed control accuracy
1,955 mL/min maximum flow
0.1–600 rpm adjustable speed range
2 Models Low-flow and high-flow configurations
Advanced Pump Technology

More control. Less interruption.

Designed to help laboratories achieve consistent results while simplifying everyday fluid handling.

01 / PRECISION

Digital Speed Control

A high-performance stepper motor delivers speed accuracy up to 0.2%, supporting controlled and repeatable liquid transfer for precise laboratory applications.

02 / EFFICIENCY

Quick Tubing Changes

Simplified tube loading, tool-free pump head replacement and an innovative occlusion design help reduce maintenance and setup time.

03 / INTEGRATION

Flexible Control Options

Operate through the built-in digital interface or integrate with external equipment using RS485 and 0–20 mA control interfaces.

Laboratory Applications

Versatile fluid handling across laboratory processes.

The LP500 supports a wide range of laboratory processes requiring accurate, controlled liquid movement and dependable operation.

✓ General Laboratory Fluid Transfer
✓ Density Gradient Tube Filling
✓ Chemical Synthesis Processes
✓ Bacterial & Cell Culture
✓ Food & Beverage Laboratories
✓ Liquid Dosing & Dispensing
✓ Laboratory Sampling
✓ Research & Development
Choose Your Configuration

Two models. One dependable platform.

Select the LP500 configuration that best suits your required flow rate and tubing size.

Low Flow Configuration

LP500-L

Ideal for lower-volume laboratory fluid handling.

1,170 mL/min

Maximum flow at 600 rpm with 4.8 mm ID tubing

  • 3.2 mm tubing internal diameter
  • 4.8 mm tubing internal diameter
  • Digital speed and direction control
  • Quick-change pump head
High Flow Configuration

LP500-H

For applications requiring greater liquid throughput.

1,955 mL/min

Maximum flow at 600 rpm with 8.0 mm ID tubing

  • 6.4 mm tubing internal diameter
  • 8.0 mm tubing internal diameter
  • Digital speed and direction control
  • Quick-change pump head

Continuous-duty operation is rated up to 400 rpm. Maximum flow rates shown are at 600 rpm. Actual flow depends on tubing and operating conditions.

Performance Data

Flow Rate Comparison.

Flow rates in mL/min using silicone tubing with a wall thickness of 1.6 mm.

Motor Speed LP500-L
3.2 mm ID
LP500-L
4.8 mm ID
LP500-H
6.4 mm ID
LP500-H
8.0 mm ID
100 rpm 100 219 310 494
300 rpm 290 608 876 1,188
600 rpm* 559 1,170 1,569 1,955

*Continuous-duty operation is rated up to 400 rpm. Flow rates vary with tubing and operating conditions.

Technical Specifications

Engineered for laboratory reliability.

Compact construction, flexible operating modes and straightforward integration.

Speed Adjustment 0.1–600 rpm
Continuous Duty Up to 400 rpm
Maximum Continuous Pressure 0.3 bar
Operating Modes Internal, external, timing, level 1 and level 2
External Control RS485 and 0–20 mA
Supply Voltage 100–240 VAC
Frequency 50/60 Hz
Ambient Temperature 0–40°C (32–104°F)
Protection Rating IP31
Weight 4.4 kg (9.69 lb)
Dimensions 316 × 180 × 197 mm (L × W × H)
Compatible Tubing Silicone, 1.6 mm wall thickness
Ordering Information

Pumps, replacement heads and tubing.

Contact CompreVac with the appropriate Welch part number for a Canadian quotation.

Product Description Welch Part Number
LP500 Low Flow Pump with Head 5501-01
LP500 High Flow Pump with Head 5502-01
ETL500 Low Flow Replacement Head 5501K-01
ETL500 High Flow Replacement Head 5502K-01
Platinum-Cured Silicone Tubing, 3.2 mm ID, 15 m 5500KT-03
Platinum-Cured Silicone Tubing, 4.8 mm ID, 15 m 5500KT-04
Platinum-Cured Silicone Tubing, 6.4 mm ID, 15 m 5500KT-06
Platinum-Cured Silicone Tubing, 8.0 mm ID, 15 m 5500KT-08

All listed tubing has a 1.6 mm wall thickness. Confirm tubing compatibility with your process fluid and operating conditions.

Frequently Asked Questions

Welch LP500 Peristaltic Pump FAQs

Answers to common questions about Welch LP500 laboratory peristaltic pumps, flow rates, tubing selection, operating controls, maintenance and Canadian availability.

What is the Welch LP500 peristaltic pump used for?

The Welch LP500 is a variable-speed laboratory peristaltic pump designed for controlled liquid transfer, dosing and filling. Applications include general laboratory fluid handling, density gradient tube filling, chemical synthesis processes, bacterial and cell culture, and food and beverage laboratory work.

What is the difference between the Welch LP500-L and LP500-H?

The LP500-L is the low-flow configuration and accepts 3.2 mm and 4.8 mm internal-diameter tubing. The LP500-H is the high-flow configuration and accepts 6.4 mm and 8.0 mm internal-diameter tubing. At 600 rpm, maximum flow is 1,170 mL/min for the LP500-L and 1,955 mL/min for the LP500-H. The appropriate model depends on the required liquid flow rate and tubing size.

What is the maximum flow rate of the Welch LP500?

The LP500-H delivers up to 1,955 mL/min at 600 rpm using 8.0 mm ID silicone tubing. The LP500-L delivers up to 1,170 mL/min at 600 rpm using 4.8 mm ID tubing. Flow rates vary according to tubing dimensions, operating speed and application conditions. Continuous-duty operation is rated up to 400 rpm.

How accurate is the Welch LP500 peristaltic pump?

The LP500 uses a digitally controlled high-performance stepper motor with speed accuracy up to 0.2%. This supports consistent pump speed for repeatable liquid transfer. Actual dispensing or dosing accuracy also depends on tubing characteristics, fluid properties, operating conditions and system calibration.

Can the Welch LP500 operate continuously?

Yes. The Welch LP500 is rated for continuous operation at motor speeds up to 400 rpm. The adjustable speed range extends from 0.1 to 600 rpm, allowing higher speeds for applications that do not require continuous operation at those speeds.

What tubing is compatible with the Welch LP500?

The LP500 uses silicone tubing with a 1.6 mm wall thickness. The LP500-L accepts 3.2 mm and 4.8 mm internal-diameter tubing, while the LP500-H accepts 6.4 mm and 8.0 mm internal-diameter tubing. Welch offers platinum-cured silicone replacement tubing in 15-metre lengths for these sizes. Chemical compatibility with the pumped liquid should be confirmed before use.

Can the Welch LP500 be controlled remotely?

Yes. The LP500 supports internal and external control, including RS485 and 0–20 mA interfaces. These options allow the pump to be integrated with suitable laboratory automation systems and external controllers. The pump also supports timing and level-based operating modes.

Is the Welch LP500 easy to maintain?

The LP500 is designed for straightforward operation and maintenance. Its pump head can be replaced without tools, while the tubing holder and occlusion design simplify tubing changes without requiring manual tube adjustments. A high-performance stepper motor provides dependable speed control for long-term laboratory use.

What is the maximum operating pressure of the Welch LP500?

The Welch LP500 has a maximum continuous system pressure of 0.3 bar. The maximum continuous operating speed is 400 rpm, and the specified ambient temperature range is 0–40°C (32–104°F).

What are the Welch LP500 pump and replacement head part numbers?

The LP500-L low-flow pump with head is part number 5501-01, and the LP500-H high-flow pump with head is 5502-01. Replacement ETL500 pump heads are 5501K-01 for low flow and 5502K-01 for high flow. CompreVac can assist with selection and ordering.

Is the Welch LP500 a vacuum pump?

No. The Welch LP500 is a peristaltic liquid-handling pump. It transfers liquid by compressing flexible tubing using a rotating pump head. It is intended for controlled liquid movement rather than generating vacuum for applications such as freeze drying or vacuum filtration. Welch also manufactures separate laboratory vacuum pump technologies.

Where can I buy a Welch LP500 peristaltic pump in Canada?

CompreVac supplies Welch laboratory pumping equipment to Canadian customers. Contact CompreVac for the LP500-L or LP500-H, replacement pump heads, compatible silicone tubing, product selection and Canadian pricing. Request an LP500 quotation or download the Welch LP500 brochure .

Looking for the right LP500 configuration?

CompreVac can help you select the appropriate Welch peristaltic pump, tubing and replacement components. Contact us to discuss your application and Canadian pricing.

Welch Laboratory Pumps

Welch-Ilmvac is a global business dedicated to providing value-added Laboratory and Life Science products. As a business unit of Gardner Denver’s Thomas Division, Welch-Ilmvac offers a broad portfolio of environmentally responsible vacuum products and services into the R&D laboratory and light industrial markets.Formed in mid-2010, Welch-Ilmvac combines the technologies and resources of two vacuum industry leaders, US-based Welch Vacuum Technology and Ilmvac GmbH (Ilmenau, Germany). With manufacturing on two continents, global distribution, and an extensive service network, Welch-Ilmvac provides expert technical solutions and value-driven vacuum products for the global marketplace. Laboratory vacuum application requirements are the primary design drivers for Welch-Ilmvac products. Basic vacuum pump designs are enhanced using advanced engineering to provide top application value to Welch-Ilmvac Customers – the right pump for the right job. Basic vacuum pump designs include diaphragm, belt driven or direct-drive rotary vane, gear, WOB-L piston, linear (armature), and scroll models as well as application-specific systems.
Get a Quote

Welch Belt Drive Rotary Vane Vacuum Pumps

Welch Belt-drive vacuum pumps are known for their ruggedness world-wide in the most demanding applications.Belt-drive vacuum pump are available in three types: DUOSEAL, CHEMSTAR and CAPTURE. DUOSEAL vacuum pumps are used in most common lab and industrial applications.  DUOSEAL pumps are available in 6 models of two-stage vacuum pumps and 2 models of one-stage pumps.CHEMSTAR pumps are designed to tolerate harsh chemical contamination with vital parts corrosion resistant and uses Welch Gold oil, a synthetic pump oil designed to resist chemical attack.CAPTURE pump is used for refrigerant recovery and transfer.On special requests, both  DUOSEAL and CHEMSTAR vacuum pumps can be fomblinized for oxygen service.Applications: Schlenk lines, freeze dryers, glove boxes, degassing, vacuum ovens, high boiling point distillations,  HVAC service.

Welch Belt Drive Rotary Vane Vacuum Pumps

Welch CRVpro Direct-Drive Rotary Vane Vacuum Pumps

CRVpro vacuum pumps are two-stage direct-driven vacuum pumps. They are nine models of CRVpro available with free air displacement from 1.8 cfm to 45.9 cfm.  Ultimate pressure to 2x10-3 torr.Depending on model, motor options include 1 Ph TEFC,  3 Ph TEFC,  and 1 Ph ex proof motors. Available on request are fomblinized CRVpro pumps for oxygen service.  Contact us for more information.Applications: Freeze dryer, short path, vacuum oven, glove box, schlenk line, mass spectrometer, HVAC service, surface coating, degassing.
‍

Welch CRVpro Direct-Drive Rotary Vane Vacuum Pumps

Welch Standard Duty Dry Vacuum Pump

Reliable WOB-L Piston pumps are perfect for many common laboratory vacuum applications. Features: Vacuum and Pressure - to 100 Torr (26"Hg). Includes Vacuum and Pressure Regulators and Gauges - simple to adjust and monitor vacuum level and delivery pressure.

Inlet Water Trap - float ball rises to seal off pump from accidental ingestion of water. Muffler quiets pump and filters discharge air. For use with dry or aqueous vapor applications only.

Welch Standard Duty Dry Vacuum Pump

Welch Diaphragm Pumps

Clean operation (oil free), low cost of ownership, highest reliability – these are just a few benefits that customers can appreciate when they use a diaphragm pump for laboratory or industrial applications. With a broad range of diaphragm pumps – ultimate vacuum from 75 to 1 mbar and peak flow rates up to 138 l/min – Welch offers specific pump families and models for a variety of uses.

Diaphragm pumps work completely without oil which has several advantages for the user, Less maintenance compared to other technologies saves time and money, Dry vacuum allows cleaner workplace and environment, Uncontaminated pumping of gases results in cleaner samples and no risk of oil back-streaming.

Welch Diaphragm Pumps